40, 76, 164, 322, 601
Features
- Steel Frame Construction
- Totally Self-Contained
- Multi-Level Annunciation
- Free Standing Installation
- May Be Installed By Your Technicians
- Full Front Graphic Display
- Functional Call Back Feature
- Enclosed Central Located
Options
- Exterior Audible / Visual Alarms
- Audible Detection Alarms
- Underfloor Coverage / Detection
- Interior Annunciation
- Remote Graphic Display
A MODULAR PROTECTION ® 1002M Control panel has been designed as a compact control panel for Special Hazard Fire Protection System applications. The microprocessor based unit is suitable to perform detection and control functions associated with the following:
• Novec™ 1230 fluid
• NFPA 12 High Pressure CO2 Systems
• NFPA 12A Halon 1301 Systems.
• NFPA 2001 CEA Systems
• NFPA 72 Local Signaling Systems
The Mod 1002M features four power limited inputs which are Class A or Class B supervised. Two detection zones are suitable for smoke detectors, thermal detectors and normally open alarm initiating devices. The detection zones are programmable for single zone or cross-zone detection. Two additional inputs are provided for manual and abort stations.
The SEVO ® 1230 system nozzles are designated to provide rapid and thorough vaporization and distribution of agent with the air in the protected space. Standard nozzles are made of aluminum. Pre-engineered system nozzles are made in three pipe sizes, 1”, 1 ½”, and 2”.
Both 180 º and 360 º nozzles were tested for a maximum area coverage using a 32' wide by 32' long enclosure.
- Five Sizes Filled at Factory in
One lb. Increments
- High Flow Rate Valve
- Electric Solenoid Operation
- Vertical Mounting
- Optional
Liquid Level Indicator
Manual Actuation
Pressure Switch
Low Pressure
Operational
- DOT/TC or • TPED
The cylinder valves are of a pressure-seated high flow rate design, in order to meet the rapid discharge time specified in NFPA 2001. Each has a brass body, a brass piston with resilient seat, a pressure releasing pilot check, a safety disc assembly, a pressure gauge, and an electric solenoid valve. This relieves the pressure above the piston and permits the piston to travel upward, thus fully opening the valve and permitting the agent to discharge through the outlet. The discharge outlet is fired with an anti-recoil plug, which is a safety device to prevent violent movement of the cylinder in the event of discharge while the cylinder valve is not connected to the piping system structure.
Downloadable Data Sheets
|